B-1000 Infant Incubator
STANDARD FEATURES:
●Servo Control Mode: air temperature;
● Parameter Displaying: set temperature,air temperature, heat power rate;
● Audible & Visual Alarms: powerfailure, sensor failure, higher & lower temp, air temperature override,fan failure, system failure;
● >37℃Preset Mode: power failure reset memory, alarm silence, keypad lock, self-testfunction;
● Hood with dual slope; 6 hand-ports;
● RS-232 Output Connector (use for networksystem);
●IV poles;
●Protective guard rail;
●Storage cabinets.
Specifications of hood
Mattress to Hood: 450 mm
Observation side of hood: Two incline
Operate port: 6 (2 Iris ports)
Tubing grommets: 4
Front access panel: 826×310 mm
Mattress Tray Size: 630×360 mm
Technical Specifications:
Power requirement ≤400VA
Temperature control mode: Air servo control
AirTemp Control Range: 20℃~37℃
Temperature override mode to: 20℃~39℃
Temperature fluctuation: ≤0.5℃
Mattress temperature uniformity: ≤0.8℃
Temperature rise time: ≤45 min
Noise level within hood environment: ≤55dB
Alarms
Power failure alarm
Fan failure alarm
Sensor failure alarm
High air temperature alarm: +3.0℃
Low air temperature alarm: -3.0℃
Over air temperature alarm: ≤38.0℃; ≤40.0℃
System failure alarm
Alarm silence function
Operational condition
Environment temperature: +20℃~+30℃
Environment relative humidity: 5%~99%
Environment air velocity of flow: <0.3m/s
Others
Infant bed tilt adjusting ±10° step-less
Mattress tray Max. load 10kg
Transfusion pole Max. load 2kg
Cabinet Max. load 6kg